Charging station G4-3 and G4-9

laddcentral bannerbild

General

Number of power outputs

9 pcs 6 mm2 supplying up to 54 charging points

Input current

32A-125A 3-phase

Incoming cable area

16 mm2 – 95 mm2 (incl. aluminum/copper)

Outgoing plinth

9 pcs 5 x 6 mm2

Max simultaneous charging power

66 kW

Number of simultaneous loads

G4-3

3 pcs, 1 to 3 phase

G4-9

9 pcs, 1 to 3 phase

Loading standards

EN61851-1 Type2, Mode3
OCPP 1.6 (charging centre)
OCPI 2.2 (loading portal)

For complete specification see the “EU Declaration of Conformity” for ChargeNode Charging Station.

Charging structure

9 internal charge controllers

Main switch

125A

Automatic fuses

G4-3

3 pcs, 32A B-KAR

G4-9

9 pcs, 32A B-KAR

Ground fault circuit interrupter

G4-3

3 pcs, Type-B remote controlled

G4-9

9 pcs, Type-B remote controlled

Energy meters

G4-3

3 pcs, MID approved

G4-9

9 pcs, MID approved

Internet connection

3G/4G/WAN/Industrial Router with dual SIM cards

Lighting control

Prepared for astrour, incl. 10 point connection terminal block

Temperature sensors

2 pcs -40 to +100C

Monitoring outputs

Overvoltage, overcurrent and earth fault

Static load balancing

Load balancing against fixed value

Dynamic load balancing

Dynamic value support for external energy meter

Temperature range (in operation)

-30⁰C to +45⁰C air temperature

Temperature range (not in operation)

-30⁰C to +65⁰C, non-condensing

Installation type

Indoor & Outdoor
– on a plinth (on the floor or in the ground)
– on the wall
– on poles

Opening

Right-handed door

Dimension charging center (HxWxD)

1160 x 760 x 250 mm

Dimension base (HxWxD)

500 x 745 x 225 mm

Dimension ‘burial leg’

800 mm (650 mm increased height)

Material

Galvanised and powder coated steel sheet 1,5 mm

Color

Black (RAL 9011)

Lock

Industrial lock, lock plunger with key

IP classification

IP44

Laddcentral